• -15%
RB-200 12 V 200 Ah lithium battery for starting and services - Relion

RB-200 12 V 200 Ah lithium battery for starting and services - Relion

RELiON lithium batteries provide more power than lead-acid batteries, increase performance, and weigh half as much.

Prodotti alternativi

Product Details

Supply voltage
12 V
Typology
Al litio
Battery Capacity
200 Ah
Length
522 mm.
Width
220 mm.
Height
267 mm.
Model
RB-200
Type of use
Start-up and services
Maintenance-free
Yes

Description

They can be charged quickly, but it is recommended to use a slower charging rate such as in 2-5 hours.Unlike other batteries, leaving them partially discharged does not reduce their life or long-term performance. Their charging capacity is about 25-50% higher than other models, which ensures prolonged use of instrumentation and prevents voltage sag as the charge decreases. Maintenance-free, they last up to 10 times longer than their lead-acid counterparts, while retaining 80% of capacity after 2000 duty cycles. Increased temperature tolerance, being able to operate safely up to 65°C and offer higher performance at low temperatures. Series or parallel connections. When connecting batteries in series or in parallel, observe the following:(1) Before putting them into service, make sure that each battery does not exceed 50mV (0.05V). This will minimize the possibility of imbalance between the batteries. If they become unbalanced, the voltage of any one battery is >50mV (0.05V), compared to another in the set, you must individually charge each battery to rebalance it. (2) Properly size the batteries in parallel: the capacity (rated in hours) when connected in parallel increases by the multiple of the batteries connected (2x, 3x, 4x, etc.). However, the rated current (discharge and charge) of batteries in parallel only increases by 75% of the multiple of the connected batteries (1.5x, 2.4x, etc.) (1.5x, 2.25x, 3x, etc.). (3) Batteries connected in series charge better as single batteries. Charging in series can cause imbalances and reduce run time, requiring occasional individual balancing charge. (4) Refer to the RELION document on instructions for series and parallel charging.LiFePO4 battery discharge. LiFePO4 batteries can be discharged to 100% of their capacity. However, to optimize performance and prevent the BMS from disconnecting it, it is recommended to limit discharge to 80%. Refer to the battery data sheet for the continuous and peak discharge rates of the specific model.When to charge LiFePO4 batteryIf LiFePO4 batteries are not fully discharged, it is not necessary to charge them after each use; they will not be damaged if left in a partial state of charge (PSOC). You can charge them after each use or when they have been discharged to 80% (20% SOC). If the BMS disconnects the battery due to low voltage, at 100% discharge, remove the load to reconnect the battery circuit and charge immediately.It is recommended to store the batteries at 50% state of charge (SOC).Use compatible battery chargers for Lithium batteries, such as ProMariner. In case of charging from alternator make sure it is compatible and has the right charging parameters.
Product added to wishlist